AdapterID 8F82h AdapterName "IBM SCSI-2 Fast/Wide Streaming-RAID Adapter/A" Numbytes 4 Address 32 Begin Device 02h 02h 03h NoDma NamedItem Prompt "Interrupt Level" choice "Level E" pos[0]=00XXXXXXb int 0eh choice "Level A" pos[0]=11XXXXXXb int 0ah choice "Level B" pos[0]=10XXXXXXb int 0bh Help "This choice allows you to set the interrupt level for the adapter. If you are in the 'Change Configuration' window, you can change the setting. Use F5 and F6 to scroll through the choices. If a setting conflicts with another, an asterisk (*) appears next to the conflicts. You must fix conflicts before you use the adapter. Use the Up and Down arrow keys to move from field to field. (If you are not in the 'Change Configuration' window and you need to change the setting, return to the 'Set Configuration' window then select 'Change configuration'.)" NamedItem Prompt "BIOS Base Address" choice "C0000-0C1FFF" pos[0]=XX00000Xb mem 0c0000h-0c1fffh choice "C2000-0C3FFF" pos[0]=XX00010Xb mem 0c2000h-0c3fffh choice "C4000-0C5FFF" pos[0]=XX00100Xb mem 0c4000h-0c5fffh choice "C6000-0C7FFF" pos[0]=XX00110Xb mem 0c6000h-0c7fffh choice "C8000-0C9FFF" pos[0]=XX01000Xb mem 0c8000h-0c9fffh choice "CA000-0CBFFF" pos[0]=XX01010Xb mem 0ca000h-0cbfffh choice "CC000-0CDFFF" pos[0]=XX01100Xb mem 0cc000h-0cdfffh choice "CE000-0CFFFF" pos[0]=XX01110Xb mem 0ce000h-0cffffh choice "D0000-0D1FFF" pos[0]=XX10000Xb mem 0d0000h-0d1fffh choice "D2000-0D3FFF" pos[0]=XX10010Xb mem 0d2000h-0d3fffh choice "D4000-0D5FFF" pos[0]=XX10100Xb mem 0d4000h-0d5fffh choice "D6000-0D7FFF" pos[0]=XX10110Xb mem 0d6000h-0d7fffh choice "D8000-0D9FFF" pos[0]=XX11000Xb mem 0d8000h-0d9fffh choice "DA000-0DBFFF" pos[0]=XX11010Xb mem 0da000h-0dbfffh choice "DC000-0DDFFF" pos[0]=XX11100Xb mem 0dc000h-0ddfffh choice "DE000-0DFFFF" pos[0]=XX11110Xb mem 0de000h-0dffffh Help "This choice allows you to choose the BIOS base address for the adapter. Each adapter must have a unique address range. Under normal circumstances, this address range does not need to be changed. If you are in the 'Change Configuration' window, you can change the setting. Use F5 and F6 to scroll through the choices. If a setting conflicts with another, an asterisk (*) appears next to the conflicts. You must fix conflicts before you use the adapter. Use the Up and Down arrow keys to move from field to field. (If you are not in the 'Change Configuration' window and you need to change the setting, return to the 'Set Configuration' window then select 'Change configuration'.)" NamedItem Prompt "I/O Address" choice "1C00-1C1F" pos[3]=XX000XXXb io 01c00h-01c1fh choice "3C00-3C1F" pos[3]=XX001XXXb io 03c00h-03c1fh choice "5C00-5C1F" pos[3]=XX010XXXb io 05c00h-05c1fh choice "7C00-7C1F" pos[3]=XX011XXXb io 07c00h-07c1fh choice "9C00-9C1F" pos[3]=XX100XXXb io 09c00h-09c1fh choice "BC00-BC1F" pos[3]=XX101XXXb io 0bc00h-0bc1fh choice "DC00-DC1F" pos[3]=XX110XXXb io 0dc00h-0dc1fh choice "FC00-FC1F" pos[3]=XX111XXXb io 0fc00h-0fc1fh Help "This choice allows you to set the I/O address for the adapter. Each adapter must have a unique address range. Under normal circumstances, this address range does not need to be changed. If you are in the 'Change Configuration' window, you can change the setting. Use F5 and F6 to scroll through the choices. If a setting conflicts with another, an asterisk (*) appears next to the conflicts. You must fix conflicts before you use the adapter. Use the Up and Down arrow keys to move from field to field. (If you are not in the 'Change Configuration' window and you need to change the setting, return to the 'Set Configuration' window then select 'Change configuration'.)" NamedItem Prompt "DMA Arbitration Level" choice "Level 8" pos[1]=X0X11000b arb 8 choice "Level 9" pos[1]=X0X11001b arb 9 choice "Level A" pos[1]=X0X11010b arb 10 choice "Level B" pos[1]=X0X11011b arb 11 choice "Level C" pos[1]=X0X11100b arb 12 choice "Level D" pos[1]=X0X11101b arb 13 choice "Level E" pos[1]=X0X11110b arb 14 choice "Level 1" pos[1]=X0X10001b arb 1 choice "Level 3" pos[1]=X0X10011b arb 3 choice "Level 5" pos[1]=X0X10101b arb 5 choice "Level 6" pos[1]=X0X10110b arb 6 choice "Level 7" pos[1]=X0X10111b arb 7 Help "This choice allows you to select the DMA channel the adapter will use to transfer data. Under normal circumstances, select . If you are in the 'Change Configuration' window, you can change the setting. Use F5 and F6 to scroll through the choices. If a setting conflicts with another, an asterisk (*) appears next to the conflicts. You must fix conflicts before you use the adapter. Use the Up and Down arrow keys to move from field to field. (If you are not in the 'Change Configuration' window and you need to change the setting, return to the 'Set Configuration' window then select 'Change configuration'.)" NamedItem Prompt "Tower Configuration" choice "2 Towers" pos[2]=X1XXXXXXb choice "1 Tower" pos[2]=X0XXXXXXb Help "This choice allows you to select between how many towers of seven drives will be presented to the user. Any messages regarding drive status are always presented in terms of bays in the tower. When each channel of the Streaming-RAID Adapter/A is connected to a different tower select the '2 Towers' Configuration and when both channels are connected to one single tower select the '1 Tower' Configuration." NamedItem Prompt "Data Parity Exception Handling Support" if ((submodel eq 28h) or (submodel eq 42h) or (submodel eq 46h) or (submodel eq 29h) or (submodel eq 43h) or (submodel eq 45h) or (submodel eq 44h) or (submodel eq 47h) ) { choice "Enabled " pos[1]=XX1XXXXXb } choice "Disabled" pos[1]=XX0XXXXXb Help "This choice allows you to enable or disable the Micro Channel data parity generation capability of this adapter for systems which support. The default condition is for systems which support the protocol." NamedItem Prompt "Micro Channel Streaming" if (submodel eq 0fdh) { choice "Disabled" pos[1]=0XXXXXXXb } else { choice "Enabled " pos[1]=1XXXXXXXb choice "Disabled" pos[1]=0XXXXXXXb } Help "This choice allows you to enable or disable the Microchannel streaming capability of this adapter. The default condition is set to ." NamedItem Prompt "INT 13 Support" if ((submodel eq 0B4h) or (submodel eq 42h) or (submodel eq 46h) or (submodel eq 0B0h) or (submodel eq 43h) or (submodel eq 45h) or (submodel eq 0fdh) or (submodel eq 44h) or (submodel eq 47h)) { choice "Enabled " pos[2]=1XXXXXXXb choice "Disabled" pos[2]=0XXXXXXXb } else { choice "Disabled" pos[2]=0XXXXXXXb choice "Enabled " pos[2]=1XXXXXXXb } Help "Enable / disable INT13 support. This provides limited support for BIOS INT 13 function calls and is required if boot devices are connected to Streaming-RAID Adapter/A." END